Hi, I am an happy lightbox
|
|
|
|
|
|
|
|
++ 32 (0)81 25 50 50
EN | NL | FR LOGIN   
PRODUCTS SECTORS SERVICES BRANDS
PRODUCTS
SECTORS
SERVICES
BRANDS
   
ANALOX Instruments

Rapid Multi-Assay Analyser - GM7

The GM7 analyser is used for Clinical & Research applications and enables researchers to obtain fast, accurate results for key analytes in clinical research studies. Its unique analysis menu includes programs for alcohol, cholesterol, glucose, glycerol, lactate and triglycerides.
QUOTATION
INFORMATION
QUOTATION
INFORMATION
DESCRIPTION BROCHURE
DESCRIPTION

GM7

The GM7 analyser is used for Clinical & Research applications and enables researchers to obtain fast, accurate results for key analytes in clinical research studies. Its unique analysis menu includes programs for acetoacetate, alcohol, ammonia,  cholesterol, creatinine, glucose, glutamine, glycerol, 3-Hydroxybutyrate, lactate, pyruvate, triglycerides, and urea

 

APPLICATION AREAS

  • Diabetes Research – Clamp studies
  • Clinical pathology
  • Metabolic studies
  • Biochemical Research
  • Sports Medicine

OPERATION

After calibration with a standard of the selected metabolite, the single injection of sample is all that is needed to obtain a result and prepare the analyser for the next analysis.

Sample injection via an accurate positive displacement pipette triggers the complete analytical cycle and a hard-copy result is printed within 20 seconds.

 

 


ORDER NUMBER

Analox-GM7

INSTRUMENT SPECIFICATION

Method > Enzymatic oxygen-rate
Sensor > Clark-type amperometric oxygen electrode
Reaction Temp. > 30°C
Display > 32 character backlit LCD
Printer > 16 column dot matrix, 1 line/sec.
Statistics > Sequential, giving mean, S.D and C.V.
Interface > Serial data port, optional Windows software available
Power > 100-250VAC, 50-60Hz, 12-15VDC, 60VA
Dimensions > 27cm(width) x 35cm(depth) x 25cm(height)
Weight > 5.8Kg

Notes:

Example data below, please see Analyte Technical Bulletins for full specifications.

 


ANALYTICAL PERFORMANCE

  PrecisionAccuracy (Method Comparisons)Linearity
Glucose > C.V. of 1.0%
@ 5mmol/L
(plasma)

Method comparison vs Hexokinase:
y (Analox) = 0.9836x - 0.1335 mmol/L,
r = 0.09991, n = 147
30.0 mmol/L (540 mg/dl) for 10 µl samples
Lactate > C.V. of 2.0%
@ 2.5 mmol/L

Method comparison for whole blood vs
YSI 23L: y (Analox) = 0.98x + 0.055 mmol/L,
r = 0.9991, n = 56
10 mmol/L (ca. 90 mg/dl) for 7 µl samples
Alcohol > C.V of 2.5%
@ 18.5 mmol/L
(ca. 85mg/dl)
(whole blood)
Method comparison for whole blood
(neutralised PCA extract) vs GC:
y (Analox) = 1.039x = 0.28 mmol/L,
r = 0.991, n = 27
43.0 mmol/L (ca. 200 mg/dl) for 5 µl samples
Urea > C.V. of 1.1 % @ 14.0 mmol/L
(ca. 85 mg/dl)
i) Method comparison vs Beckman urease
conductimetric proceedure:
y(Analox) = 0.993x + 0.15 mmol/L,
r = 0.998, n = 100
ii) Method comparison vs Urease/Berthelot method:
y(Analox) = 1.01x - 0.108 mmol/L,
r = 0.999, n = 93
45 mmol/L (ca. 270 mg/dl)

 


ACCESSORIES

For a full list of ordering info please go to support tab.

GMRD-100/103/102 >

Lactate reagent kit for lysed whole blood - 100/250/1000 analyser cycles, including 8.0mmol/L standard

GMRD-002A >

Glucose oxidase reagent, 360 analyser cycles

GMRD-011 >

Glucose standard, 8mmol/L, 30ml

GMRD-023 >

Heparinised capillaries for plasma preparation, pack of 500

GMRD-024 >

Heparinised capillaries for plasma preparation, pack of 1000

GMRD-029/023/024 >

Heparinised capillaries for plasma preparation, packs of 100/500/1000

GMRD-053/054 >

Whole blood collection capillaries, pack of 500/1000

GMRD-074 >

Lactate Quality Control serum, 4 x 0.5ml

GMRD-084 >

Cholesterol reagent kit, 50 tests, incl. standard

GMRD-090/093/092 >

Lactate reagent kit, 100/250/1000 analyser cycles, including 8.0mmol/L standard

GMRD-110(050) >

Ethanol standard, 50mg/dl, 4 x 1ml

GMRD-110(100) >

Ethanol standard, 100mg/dl, 4 x 1ml

GMRD-110(200) >

Ethanol standard, 200mg/dl, 4 x 1ml

GMRD-110(300) >

Ethanol standard, 300mg/dl, 4 x 1ml

GMRD-110D4 >

Alcohol Quality Control serum, 4 x 0.5ml

GMRD-113 >

Alcohol reagent kit, 70 analyser cycles

GMRD-113J >

Alcohol reagent kit, 8 x 50ml (8 x 70 analyser cycles)

GMRD-130 >

3-hydroxybutyrate reagent kit, 20-45 tests, incl. standard

GMRD-140 >

Pyruvate reagent kit, 20-40 tests, incl. standard

GMRD-150 >

Glutamine reagent kit, 50 tests, incl. standard

GMRD-162 >

Ammonia reagent kit, 20-40 tests, incl. standard

GMRD-170 >

Creatinine reagent kit, 40-80 tests, incl. standard

GMRD-177 >

Glycerol reagent kit, 140 analyser cycles, incl. standard

GMRD-180 >

Acetoacetate reagent kit, 20-40 tests, incl. standard

GMRD-195 >

Triglycerides reagent kit, 140 analyser cycles, incl. standard

Notes:

N/A

BROCHURE
ANALOX Instruments website
ANALOX Instruments
A wide range of analytes (glucose, ethanol, lactate, ammonia, sucrose, glutamine, glycerol...) for Clinical & Research and the Industrial & Biotechnology applications.
Prices are quoted in euro (taxes excluded) and apply in the Benelux (recycling fee included). They are subject to change without notice. We reserve the right to adjust pricing errors and to limit quantities.

FOLLOW US ON  FOLLOW US: