PARR Instr. Moline

High Pressure Reactors - 3750 & 7500 ml (Series 4550)

Series 4550 1 and 2 Gallon Reactors These 4550 Reactors extend the size range of the 4530 Series to 1 and 2 gallon 3 75 and 7 5 liter sizes providing excellent facilities for pilot plant studies
QUOTATION
INFORMATION
chemical@analis.be
++(0)9 243 77 10
QUOTATION
INFORMATION
chemical@analis.be ++(0)9 243 77 10
DESCRIPTION DOWNLOADS
DESCRIPTION

Series 4550 1 and 2 Gallon Reactors

These 4550 Reactors extend the size range of the 4530 Series to 1 and 2 gallon (3.75 and 7.5 liter) sizes, providing excellent facilities for pilot plant studies. They can be furnished with either a self-sealing O- ring closure for working temperatures up to 225 °C, or with a flat, PTFE gasket for higher temperatures to 350 °C. Both fixed head and moveable head designs are available. The moveable head, Model 4551 and 4552, reactors are designed so that they can be opened or closed conveniently without removing the cylinder and without auxiliary handling equipment. The split-ring cover clamp sections can be moved into place from the sides, and the cap screws can be tightened with the vessel in place in its heater. The fixed head versions, Model 4553 and 4554 (Pictured is the 4554 Reactor, Two Gallon Vessel, Opened to Show the Internal Fittings and Serpentine Cooling Coil), allow the head (and the connections made to it) to remain in place while the cylinder and heater are lowered with the aid of the included pneumatic lift system.

The 1 gallon size is usually recommended for high viscosity polymer studies, with a bottom drain valve added for convenient product recovery. As with the smaller floor stand models, these larger, self- contained systems can be equipped with a variety of attachments, such as: condensers, solids charging port, bottom drain, special motors, special heaters, jacketed vessels and automatic valves and regulators. Because of the higher wattage heaters for these reactors, all models in the 4550 Series require a 230 volt power supply.

Series 4550 Reactor Specifications

Shading indicates specifications that change within models

Model Number

4551

4552

4553

4554

Sizes, Gallon (Liter)

1 (3.75)

2 (7.50)

1 (3.75)

2 (7.50)

Maximum Pressure

1900 psi (130 bar)

Maximum Temp°C

with FKM 0-ring

225 °C

with FFKM 0-ring

275 °C

with PTFE Flat Gasket

350 °C

Vessel Style

Removable

Fixed Head

Reactor Mounting

Cart

Floor Stand

Closure (Cap Screws)

Split-Ring (6)

Valve Connections

1/4"NPT Male

Magnetic Stirrer, Model No.

A1180HC*

Maximum Torque

60 Inch-Pounds

Impeller(s), 6-Blade

2

Pressure Gage Size

4.5 inches

Range

0-2000 psi (140 bar)*

Temperature Measurement

Thermowell

Cooling Coil

Optional

Style

Serpentine or Spiral

Bottom Drain Valve

A465VB

Heater Style

Calrod

Heater Power Watts

2250

3750

2250

3750

Stirrer Motor

1/2 hp variable speed*

Electrical Supply

Volts

230

Maximum Load

16 amps

18 amps

16 amps

18 amps

Vessel Dimensions

Inside Diameter

6.0 inches

Inside Depth,inches

8.6

17.2

8.6

17.2

Weight of Vessel, pounds

95

120

115

140

Reactor Dimensions

Width, inches

35

20

Depth, inches

18

30

Height, inches

50

75

Weight, pounds

265

295

315

345

Spare Parts Kit

4559M

DOWNLOADS