Hi, I am an happy lightbox
|
|
|
|
|
|
|
|
++ 32 (0)81 25 50 50
EN | NL | FR LOGIN   
PRODUCTS SECTORS SERVICES BRANDS
PRODUCTS
SECTORS
SERVICES
BRANDS
   
BECKMAN COULTER

Therapeutic Drug Monitoring : QMS Everolimus Immunoassay (EVR)

Now available on the BECKMAN COULTER AU480/680/5800 series:A new comprehensive menu of mmunosuppressive drug monitoring kits: QMS® Tacrolimus, QMS® Everolimus, CEDIA® Cyclosporine Plus and CEDIA® Mycophenolic Acid
QUOTATION
INFORMATION
bioclinical@analis.be
081 25 50 50
QUOTATION
INFORMATION
bioclinical@analis.be 081 25 50 50
DESCRIPTION DOWNLOAD
DESCRIPTION
Therapeutic Drug Monitoring :
QMS Everolimus Immunoassay (EVR)
for the BECKMAN COULTER  AU480/AU680/AU5800 Clinical Chemistry Systems

The Thermo ScientificTM QMS® Everolimus assay is intended for the quantitative determination of everolimus in human whole blood on automated clinical chemistry analyzers. The results obtained are used as an aid in the management of organ transplant patients receiving everolimus therapy. This in vitro diagnostic device is intended for clinical laboratory use only.

The QMS Everolimus assay is a homogeneous particle-enhanced turbidimetric immunoassay. The assay is based on competition between drug in the sample and drug coated onto a microparticle for antibody binding sites of the everolimus antibody reagent. The everolimus coated microparticle reagent is rapidly agglutinated in the presence of the anti-everolimus antibody reagent and in the absence of any competing drug in the sample. The rate of absorbance change is measured photometrically. When
a sample containing everolimus is added, the agglutination reaction is partially inhibited, slowing down the rate of absorbance change. A concentration-dependent classic agglutination inhibition curve can be obtained with the maximum rate of agglutination at the lowest everolimus concentration and the lowest agglutination rate at the highest everolimus concentration.


Feature s of the Everolimus Assay


› Ready-to-Use liquid reagent
› Low-End sensitivity (LDD=0.3 ng/mL)
› Reportable range (1.5 – 20 ng/mL)
› Reproducibility across assay range

 

 

DOWNLOAD
BECKMAN COULTER website
BECKMAN COULTER
Solutions and systems for clinical diagnostics (hematology, biochemistry, immunoassays, flow cytometry. Solutions for industry & research, for genetics, proteomics and cellular analysis. Lab automated workstation & liquid handling workstation.
Prices are quoted in euro (taxes excluded) and apply in the Benelux (recycling fee included). They are subject to change without notice. We reserve the right to adjust pricing errors and to limit quantities.

FOLLOW US ON  FOLLOW US: