Cell counters & viability analyzers

Beyond Cell Counting and Viability: Advanced Solutions for Cell health Analysis


Request a demo View products

Your processes always require a better understanding, prediction and influence of the factors that underpin cell health, proliferation, biological functions and cell death.
To meet these needs, Analis offers a wide range of research solutions for cell analysis allowing for example the counting and analysis of cell viability, but also: the analysis of metabolites in culture media, analysis by flow cytometry, cell sorting, automation of pipetting operations, aseptic handling, washing and harvesting of cells, etc.

NEW

 Vi-CELL BLU Analyzer Integration with Sartorius Ambr® 250 


EXPLORE MORE 



 
 

Your legacy Vi-CELL XR cell counter and viability analyser is now replaced by the Vi-CELL BLU!

The faster Vi-CELL BLU automates the Trypan Blue Dye Exclusion method for cell viability analysis. The Vi-CELL BLU expedites processing by now having the option to use a 24-position sample carousel or a 96 well plate for sample delivery.

Contact us for info or request a demo

Guidance on migration from Vi-CELL XR to Vi-CELL BLU

Beckman Coulter summarized  the Vi-CELL BLU Matching Cell Counts with the Vi-CELL XR into an application note detailing step-by-step process for transferring a cell counting method from a Vi-CELL XR analyzer to a Vi-CELL BLU analyzer.

View application note

Ask our Experts

Our products

BECKMAN COULTER LIFE SCIENCES
Vi-CELL BLU Reagent Pack (Qty 4)
Reference : BEC-C39291

We’ve improved the Vi-CELL reagent pack to make it easier to use. The Vi-CELL reagents you know and trust are now packaged in a convenient ready-to-load kit. Simply open the instrument reagent panel and slide in the reagent pack. Each pack can be used for 310 activities before changing. Packs are easy to replace with no mess. Say goodbye to wrangling with tubes and splattering dye when you change out reagents. Your lab coat will thank you!

Each reagent pack contains:
-
Trypan Blue bottle
-Waste bottle
-Buffer solution bottle
-Disinfectant bottle
-Cleaning agent bottle

Each pack also includes an RFID tag that tells you how many activities are remaining on the pack. No more guessing on remaining reagent amounts or running out in the middle of a critical series of tests.
The embedded RFID tag gives important information about each pack to your Vi-CELL BLU instrument:
-Lot number
-Expiration date
-On-board life (90 days)
-Activities remaining
-Part number
There are no more cardboard packs. The new reagent pack is made of plastic and easy to wipe down in clean room situations. Another advancement in the new reagent pack is that the reagent pack lid, tray, and bottles are recyclable.

C39291 is for a quad pack (Qty 4) of Vi-CELL BLU reagent packs.
To purchase a single Vi-CELL BLU reagent pack, see C06019 - Vi-CELL BLU Reagents Qty 1

BECKMAN COULTER LIFE SCIENCES
Vi-CELL BLU Reagent Pack (Qty 1)
Reference : BEC-C06019

We’ve improved the Vi-CELL reagent pack to make it easier to use. The Vi-CELL reagents you know and trust are now packaged in a convenient ready-to-load kit. Simply open the instrument reagent panel and slide in the reagent pack. Each pack can be used for 310 activities before changing. Packs are easy to replace with no mess. Say goodbye to wrangling with tubes and splattering dye when you change out reagents. Your lab coat will thank you!

Each reagent pack contains:
-
Trypan Blue bottle
-Waste bottle
-Buffer solution bottle
-Disinfectant bottle
-Cleaning agent bottle

Each pack also includes an RFID tag that tells you how many activities are remaining on the pack. No more guessing on remaining reagent amounts or running out in the middle of a critical series of tests.
The embedded RFID tag gives important information about each pack to your Vi-CELL BLU instrument:
-Lot number
-Expiration date
-On-board life (90 days)
-Activities remaining
-Part number
There are no more cardboard packs. The new reagent pack is made of plastic and easy to wipe down in clean room situations. Another advancement in the new reagent pack is that the reagent pack lid, tray, and bottles are recyclable.

C06019 is for a single Vi-CELL BLU Reagent pack.
To purchase a quad pack of Vi-CELL BLU reagents, see C39291 - Vi-CELL BLU Reagents Qty 4

BECKMAN COULTER LIFE SCIENCES
Sample Vials Bag for Vi-CELL BLU Analyzers
Reference : BEC-C99606

Bag contains 500 sample vials for use with the Vi-CELL BLU Analyzer. Minimum volume required in sample vial is 200µm. In FAST mode, a minimum volume of 170µm is required in the sample vial. 

Note : This product replace previous reference BEC-C24843 Sample Vials (350 vials each bags) 

BECKMAN COULTER LIFE SCIENCES
Focus control (1 x 15mL)
Reference : BEC-175474

The Vi-CELL Focus Control is used during the autofocusing procedure when the system requires re-focusing. The focus control beads help the system refocus and offer a new recommended focus position. The cup of focus control is run similar to a sample run using the Vi-CELL carousel sample delivery method.

For use in the Vi-CELL BLU and Vi-CELL XR cell viability analyzers.

BECKMAN COULTER LIFE SCIENCES
Vi-CELL™ 1M, Concentration control (1 x 20ml)
Reference : BEC-175478

For use with the Vi-CELL XR Cell Viability Analyzer. 
The concentration control consists of a mixture of latex beads at 1x106 beads/mL concentration.
It is recommended to run daily to verify that the Vi-CELL is counting properly. 

Your legacy Vi-CELL XR cell counter and viability analyzer is now replaced by the Vi-Cell BLU

BECKMAN COULTER LIFE SCIENCES
Vi-CELL™ Quad pack for integrated systems: 4 reagent packs, no vial (XR version)
Reference : BEC-B94987

These reagents are for use in the Vi-CELL™ XR Cell Viability Analyzer when the instrument is integrated to an automated sampling device. Please note that this package does not include sample vials.

Trust is an integral component of any relationship. So, let us illustrate the value and peace of mind that you will receive when you purchase Vi-CELL™ Reagents from Beckman Coulter Life Sciences. Vi-CELL™ Reagents offer:
-Validated reagent with appropriate cleaning and disinfectant solutions
-Certificate of Analysis for each lot
-Service contract guarantee

Don’t put your experiments at risk, always use Beckman Coulter reagents, a company you know and trust. Using Non-Beckman Coulter Vi-CELL™ reagents may result in frequent light intensity errors and clogging of the fluid lines, creating unnecessary Service visits. Our in-house testing has demonstrated that using Non-Beckman Coulter reagents with the Vi-CELL™ leads to gradual darkening of the flow cells which lowers the background intensity and generates a light intensity error message. This issue is corrected if a decontamination cycle is performed and the Beckman Coulter Vi-CELL™ Reagent Pak is subsequently used on the system.

Did you yet think about an upgrade to the next Vi-CELL generation ? Look at the new Vi-CELL BLU

https://analis.odoo.com/categ/cell-counters-viability-analyzers